Replaces code 023-520
This kit allows the connection between the power conductors, the ground conductor and signal cables (if available) in the jacketed cable from the pump to the drop cable. Replaces code 023-520
The junction, when properly performed, provides:
Electrical continuity in the power phases and the ground wire
Electrical continuity in the two signal wires (if available. If not using a signal cable use the rubber bung to block the second hole)
Insulation between the phases, between each phase and ground, and between each phase and the signal wires (if available)
Watertight seal up to a maximum depth of 150 m / 500 ft submergence.
The kit consists of:
4 yellow connectors for power cables from 4mm (AWG 11) to 6mm (AWG 9)
4 blue connectors for power cables from 1.5mm (AWG 15) to 2.5mm (AWG 13)
4 red connectors for signal cables (if available) from 0.75mm (AWG 18) to 2,5mm (AWG 13)
The type of connector used corresponds to the section of cable that you are joining
A resin container sleeve (with cap on the cable jacket) to contain and protect the junction and casting resin
A jar of resin, a jar of hardener, and a mixing palette
Regardless of the section being joined, the minimum diameter of the cable junction should be (in order to prevent leakage of the sealing resin during the casting) 12mm / 1/2 in. For the power cable (big hole) 8 mm / 5/16 in. For the signal cable, if available (small hole).